Printer-friendly version

This is a Windows Server 2003 specific issue. As a workaround, resync the disks in Windows Disk Management

This article applies to:

  • Acronis Disk Director 11 Advanced Server

Symptoms

  1. Using Acronis Disk Director 11 Advanced Server in Windows Server 2003, you create a Mirrored RAID from your basic system disk;
  2. You commit the operation and reboot the system to apply the changes;
  3. After the reboot, resyncing starts and Windows Server 2003 reboots the system again;
  4. After the second reboot the Mirrored RAID is in the Failed redundancy state.

Cause

This is specific only to the following conditions (all of which should be true):

  • The operating system is Windows Server 2003;
  • You created a Mirrored RAID from your basic system disk.

Solution

Preventive

  1. Create a dynamic volume from the system disk and commit the operation.
  2. Once the system volume is dynamic, perform the operation.

Resultive

Resync created Mirrored RAID in Windows Disk Management.

More information

Acronis Development Team is working on fixing the issue.

Provide feedback on this information

Please use the form below to send us your comments. We read all feedback carefully.

Please note that we cannot individually respond to all comments. We do read, analyze and work to improve our content, products and services based off the feedback we receive. Should you need technical or customer service assistance please use our Contact Support Wizard.

Thank you for taking the time to send us your thoughts, we truly value your input.

To protect your privacy, do not include contact information in your feedback.